Generated from the public tank demo’s invented site inputs. Preliminary and not for construction; no engineer has approved or released this sample. Sources, rates and reports are illustrative.
01 / Design documentation
The detail behind the decision.
Dimensioned views, connection schedules and site context, drawn from the same demo inputs. Two presentation sheets accompany the original source files.
NF-DEMO-TK101-GA-01 · A3 / 1:100PRELIMINARY · NO ENGINEERING RELEASE
Dimensions and schedules come from the demo’s starting case. Original drawings, IFC models, design basis and exclusions remain in the ZIP. These sheets add presentation detail, not engineering checks.
The complete CSV retains the sizing basis, exclusions and unconfirmed code references.
02 / Quantities
Take the numbers with you.
Inspect the shell schedule as an ordinary spreadsheet file. The full set also contains nozzle and tie-in schedules, instrument and cable lists, and an illustrative estimate with its missing inputs visible.
TK-101 shell shares volume with Scanned object (other).
Source · revision 2026-09
area4-scan.las (example)
What the source cannot show
A scan shows the surfaces the scanner saw: what was behind other objects, inside them or below ground is not in it, and empty voxels may be shadows.
CLASH / TK-101 foundationScanned object+
TK-101 foundation shares volume with Scanned object (other).
Source · revision 2026-09
area4-scan.las (example)
What the source cannot show
A scan shows the surfaces the scanner saw: what was behind other objects, inside them or below ground is not in it, and empty voxels may be shadows.
CLEARANCE / TK-101 shellPump P-201+
Pump P-201 is 720 mm from the shell, inside the 1500 mm maintenance rule.
Source · revision F
MA-1: Owner standard ST-12 §6 (example)
What the source cannot show
Drawings show what was drawn at their revision: as-built changes, below-ground services and objects nobody drew are not on them, and an object read from them is a box.
NOT SHOWN / TK-101 shellarea+
16 plan points within 2 m of the tank are covered by no source: what is there is not shown in the source, and is not taken as empty.
Source · revision F; C; 2026-09
Area 4 layout 100-001 (example); area4-structures.ifc (example); area4-scan.las (example)
What the source cannot show
No source covers these points.
03 / Findings
Know what still needs an answer.
The starting placement has clashes, a maintenance-clearance finding and gaps in source coverage. Open each finding to see its source and limits.
This is check output, not a signed review. A real assignment needs the named engineer’s review and release under the agreed scope.